Wiring The Terminals; Wiring To The Screwless Clamping Terminal Block - Omron NX-ILM400 User Manual

Machine automation controller nx-series io-link master unit
Hide thumbs Also See for NX-ILM400:
Table of Contents

Advertisement

4 Installation and Wiring
4-3

Wiring the Terminals

This section describes how to wire the terminals on the IO-Link Master Unit.
Make sure that the voltages and currents that are input to the Units and slaves are within the speci-
fied ranges.
Inputting voltages or currents that are outside of the specified ranges may cause accidents or fire.
Be sure that all terminal screws and cable connector screws are tightened to the torque specified in
the relevant manuals. The loose screws may result in fire or malfunction.
4-3-1

Wiring to the Screwless Clamping Terminal Block

This section describes how to connect wires to the screwless clamping terminal block, the installation
and removing methods, and functions for preventing incorrect attachment.
You can connect ferrules that are attached to the twisted wires to the screwless clamping terminal
block. You can also connect the twisted wires or the solid wires to the screwless clamping terminal
block. If you connect the ferrules, all you need to do to connect the wires is to insert the ferrules into the
terminal holes.
Wiring Terminals
The terminals to be wired are as follows.
• I/O power supply terminals
• I/O terminals
Applicable Wires
The wires that you can connect to the screwless clamping terminal block are twisted wires, solid wires,
and ferrules that are attached to the twisted wires. The following section describes the dimensions and
processed methods for applicable wires.
4 - 12
WARNING
Caution
NX-series IO-Link Master Unit User's Manual (W567)