Appendices
 When Using an NJ/NX/NY-series Controller
The items that are used in the version corresponding table for functions are given below.
Change or
Function
addition
Func-
Indicates
tions of
whether the
NX Units.
function was
newly added
or changed.
The version corresponding table for functions is as follows.
• You can also use the added or changed functions with the unit versions/versions given in the table
or with later/higher versions.
• Depending on the type and model of the Unit to which the NX Unit is connected, some Units do
not have the corresponding versions given in the table. If a Unit does not have the specified ver-
sion, support is provided by the oldest available version after the specified version. Refer to the
user's manuals for the specific Units for the relation between models and versions.
• If you use the corresponding unit versions/versions given in the following table or later/higher ver-
sions, refer to the version information in the user's manual for the Communications Coupler Unit,
CPU Unit, and Industrial PC.
Change
Function
or addi-
tion
Initial I/O alloca-
Change
*2
tion value
Digital input col-
Addition NX-ILM400
lection
Addition of NX
Addition NX-ILM400
*4
objects
*1. Refer to the user's manual of the EtherNet/IP Coupler Unit for the unit versions of EtherNet/IP Units corresponding to Eth-
erNet/IP Coupler Units.
*2. The following I/O allocations are enabled by default.
Digital Input Data
Digital Output Data
*3. The CX-ConfiguratorFDT with version 2.2 or higher can be used if it is connected to the peripheral USB port on the Eth-
erNet/IP Coupler Unit.
*4. The following objects are added.
Vendor Name of the Last Connected IO-Link Device
Product Name of the Last Connected IO-Link Device
Vendor Name
Product Name
A - 42
NX Unit
Model
Unit version
Coupler Unit
Model
Unit versions
Unit versions
of the NX
of EtherNet/IP
num-
bers of
Units that are
Coupler Units
NX
compatible
that are com-
Units.
with the func-
patible with the
tion.
NX Units with
the function.
NX Unit
Model
Unit version
NX-ILM400
Ver.1.1
Ver.1.1
Ver.1.1
Corresponding unit version/version
EtherNet/IP
CPU Unit or
Industrial PC
Unit versions
of the
NJ/NX-series
CPU Units or
NY-series
Industrial PCs
that support
the NX Units.
Corresponding unit version/version
Ether-
CPU Unit or
Net/IP Cou-
Industrial
pler Unit
Ver.1.2
Ver.1.14
Ver.1.2
Ver.1.14
Ver.1.2
Ver.1.14
NX-series IO-Link Master Unit User's Manual (W567)
Sysmac Stu-
CX-Configura-
dio
torFDT
Sysmac Stu-
The version of
dio versions
the CX-Config-
that are com-
uratorFDT that
patible with the
supports the
NX Units, Eth-
IO-Link Master
erNet/IP Cou-
Unit.
pler Units,
CPU Units,
and Industrial
PCs.
*1
Sysmac
CX-Config-
Studio
uratorFDT
PC
Ver.1.20
Ver.2.4
Ver.1.20
Ver.2.4
Ver.1.20
Ver.2.4
*3
*3
*3