Viessmann VITOLIGNO 300-P Service Instructions Manual page 76

Pellet boiler
Table of Contents

Advertisement

Codes
Code 2
(cont.)
Coding in the delivered condition
A7:0
Without mixer economy
function
A9:7
With pump idle time:
Heating circuit pump
"OFF" if set value is modi-
fied by changing the
operating mode or chang-
ing the set room temper-
ature
AA:2
With output reduction
(reduced heat transfer by
closing the mixer)
AB:20
Code "AA:2" must be
selected:
Minimum mixer position
when reducing output 10
%
B0:0
With remote control:
Heating mode/reduced
mode: weather-compen-
sated
B2:8
With remote control unit
and for the heating circuit,
operation with room tem-
perature hook-up must be
programmed:
Room influence factor 8
B5:5
With remote control:
With room temperature-
dependent heating circuit
pump logic function
76
Possible change
A7:1
With mixer economy func-
tion (extended heating cir-
cuit pump logic) (see
page 58)
A9:0
Without pump idle time
A9:1
Pump idle time adjustable
to
from 1 to 15
A9:15
AA:0
Without output reduction
AA:1
No function
AB:0
Value adjustable from 0 to
to
100 %;
1 step ≙ 0.5 %
AB:200
B0:1
Heating mode: weather-
compensated
Reduced mode: with room
temperature hook-up
B0:2
Heating mode: with room
temperature hook-up
Reduced mode: weather-
compensated
B0:3
Heating mode/reduced
mode: with room tempera-
ture hook-up
B2:0
Without room influence
B2:1
Room influence factor
to
adjustable from 1 to 31
B2:31
B5:0
Without room temperature-
dependent heating circuit
pump logic function