Viessmann VITOLIGNO 300-P Service Instructions Manual page 62

Pellet boiler
Table of Contents

Advertisement

Codes
Code 2
(cont.)
Coding in the delivered condition
04:0
Do not adjust
05:0
Do not adjust
06:...
Maximum boiler water
temperature limit
Delivered condition
specified by the boiler
coding card
08:0
Central fault message
connection at plug gÖ
17:...
Delivered condition
specified by the config-
ured supply system (see
chapter "Configuring the
supply system")
Parameter
address 17:...
0
1
2
3
4
5
Coding in the delivered condition
21:0
No hours run interval set
for service
22:0
No fuel consumption
selected for service
23:0
No time interval selected
for service
24:0
The service display is
reset
62
Supply system
Vacuum supply system with room discharge from the storage
room
Screw conveyor supply system with room discharge from the stor-
age room
Pellet supply from the pellet hopper (intermediate container)
Vacuum supply system from the pellet silo
Screw conveyor supply system from the pellet silo
Vacuum supply system with mole
Possible change
06:...
Subject to boiler output
(specified by the boiler cod-
ing card)
08:1
Boiler soft start connection
at plug gÖ (see page 124)
17:0
For supply systems, see
to
the following table (see
17:5
also page 12)
Possible change
21:1
The number of hours run
to
before the burner should
21:100
be serviced is adjustable
from 100 to 10,000 h;
1 step ≙ 100 h
22:1
Input of 0.1 to 25.5 t;
1 step ≙ 0.1 t
to
22:255
23:1
Interval adjustable from 1
to
to 24 months
23:24
24:1
Service display (address
set automatically)