Viessmann VITOLIGNO 300-P Service Instructions Manual page 59

Pellet boiler
Table of Contents

Advertisement

Code 1
(cont.)
Coding in the delivered condition
Set changeover
A9:7
With pump idle time:
Heating circuit pump
"OFF" if set value is modi-
fied by changing the
operating mode or chang-
ing the set room temper-
ature
Room shutdown
B5:5
With remote control:
With room temperature-
dependent heating circuit
pump logic function
Parameter
With heating circuit pump logic function:
address B5:...
Heating circuit pump "OFF"
1
RT
2
RT
3
RT
4
RT
5
RT
6
RT
7
RT
8
RT
Coding in the delivered condition
Minimum limit
C5:20
Electronic minimum flow
temperature limit 20 °C
(only enabled during
operation with standard
room temperature)
Maximum limit
C6:75
Electronic maximum flow
temperature limit set to
75 °C
> RT
+ 5 K
actual
set
> RT
+ 4 K
actual
set
> RT
+ 3 K
actual
set
> RT
+ 2 K
actual
set
> RT
+ 1 K
actual
set
> RT
actual
set
− 1 K
> RT
actual
set
− 2 K
> RT
actual
set
Possible change
A9:0
Without pump idle time
A9:1
Pump idle time adjustable
to
from 1 to 15
A9:15
B5:0
Without room temperature-
dependent heating circuit
pump logic function
B5:1
With room temperature-
to
dependent heating circuit
B5:8
pump logic function (see
the following table)
Heating circuit pump "ON"
RT
< RT
actual
RT
< RT
actual
RT
< RT
actual
RT
< RT
actual
RT
< RT
actual
RT
< RT
actual
RT
< RT
actual
RT
< RT
actual
Possible change
C5:1
Minimum limit adjustable
to
from 1 to 127 °C
C5:127
C6:10
Maximum limit adjustable
to
from 10 to 127 °C
C6:127
Codes
+ 4 K
set
+ 3 K
set
+ 2 K
set
+ 1 K
set
set
−1 K
set
−2 K
set
−3 K
set
59