Further details regarding the individual steps
Standard room temperature
110
A
C
D
Adjustment of the standard room tem-
perature from 20 to 26 °C
A Boiler water temperature or flow
temperature in °C
B Outside temperature in °C
C Set room temperature in °C
Reduced room temperature
110
A
C
D
Adjustment of the reduced room temper-
ature from 3 to 14 °C
A Boiler water temperature or flow
temperature in °C
B Outside temperature in °C
C Set room temperature in °C
26°C
20°C
-20°C
B
E
14°C
3°C
B -20°C
E
Commissioning, inspection, maintenance
D Heating circuit pump OFF
E Heating circuit pump ON
Press the following keys:
1. "MENU".
2. |/~ to select the heating circuit.
3. d
to confirm.
4. |/~ for "Standard room temp.".
5. d
to confirm.
6. |/~ for the required value.
7. d
to confirm.
D Heating circuit pump OFF
E Heating circuit pump ON
Press the following keys:
1. "MENU".
2. |/~ to select the heating circuit.
3. d
to confirm.
4. |/~ for "Red. room temp.".
5. d
to confirm.
6. |/~ for the required value.
7. d
to confirm.
(cont.)