Viessmann VITOLIGNO 300-P Service Instructions Manual page 65

Pellet boiler
Table of Contents

Advertisement

Code 2
(cont.)
Coding in the delivered condition
34:5
Only in systems with a
heating water buffer cyl-
inder and code "BB:1",
the following must be
selected:
For a description, see
page 56
35:20
Only in systems with a
heating water buffer cyl-
inder and code "BB:1",
the following must be
selected:
For a description, see
page 56
45:0
Without heating water
buffer cylinder
46:45
Only in systems with a
heating water buffer cyl-
inder:
Return temperature rais-
ing pump "ON" if the
boiler water temperature
exceeds 45 °C
47:10
Only in systems with a
heating water buffer cyl-
inder:
Integral start threshold
set to 10 K x min (see fol-
lowing description)
If the buffer cylinder temperature (top sensor) falls by a value below the set flow
temperature, the burner will start after a specified delay.
Example:
Code "47:10"
Possible change
32:100
For a smaller output reduc-
tion, set a high value.
34:0
Value adjustable from 0 to
to
20 K
34:20
35:0
Value adjustable from 0 to
to
30 K
35:30
45:1
With heating water buffer
cylinder
45:2
With heating water buffer
cylinder with integral DHW
heating (combi cylinder)
(Observe coding address
"61")
46:0
Value adjustable from 0 to
to
80 °C
46:80
47:0
Integral start threshold
to
adjustable from 0 to 100 K
47:100
x min
Codes
65