Checking Procedure of Electrical Eomponents
Stator coil

Pulsar coil

Ignition coil

Suppressor Cap
Battery
Horn
Relay Starter
Starter motor
IC Flasher
RR Unit

MEASURING INSTRUMENT

Multimeter

STARTER COIL

✰ ✰ ✰ ✰ ✰ SPECIFICATION
Resistance mode - Across any two wires
✰ ✰ ✰ ✰ ✰ CHECKING PROCEDURE
Set the multimeter in resistance mode.
Check the Resistance between wires
a. Yellow 1 to yellow 2 - 0.8 to 1.5 ohms
b. Yellow 2 to yellow 3 - 0.8 to 1.5 ohms
c. Yellow 3 to yellow 1 - 0.8 to 1.5 ohms
PULSAR COIL
✰ ✰ ✰ ✰ ✰ SPECIFICATION
Resistance mode - Across the wires
180 - 240
✰ ✰ ✰ ✰ ✰ CHECKING PROCEDURE
Set the multimeter in resistance mode.
Check the Resistance between
a. Green to white wire.
IGNITION COIL
✰ ✰ ✰ ✰ ✰ SPECIFICATION
Resistance mode across
a. Between Brown to Red/white 4 to 8
ohms.
b. Between Brown to HT lead 12.5 to 16
Kilo Ohms.
✰ ✰ ✰ ✰ ✰ CHECKING PROCEDURE
Set the multimeter in resistance mode.
Check the Resistance between
a. Brown to Red/white(Primary)
b. Brown to HT lead (Secondary)
10-7
(ohms).