iPATH Agility Controller

4.3.2 When adding Agility units

When new Agility transmitters and receivers are added to a network, they are designed to automatically announce themselves* to
the iPATH Agility Controller. Once the iPATH Agility Controller receives their announcement(s), the Agility units will be added to
the administrator's view of the Dashboard (Note: If adding a pre 3.3 Agility then the Agility unit must be trusted first, then
upgraded to 3.3 (or above) and then can be configured). From here you can then begin to configure each new Agility unit.
* Agility units can be configured either from their own browser-based configuration utility or via the iPATH Agility Controller.
Once an Agility unit has been configured in one way, it cannot be reconfigured using the other method without undergoing a
factory reset. This policy is in place to help prevent accidental overwriting of configurations. It also means that once an Agility unit
has been locally configured, it will not announce itself to the iPATH Agility Controller upon being added to a network. Please see
below for details about resetting an Agility unit.

4.3.3 If a Agility unit is not located

There are several reasons why an Agility unit might not be located by iPATH:
• The Agility unit has been locally configured or is otherwise not using its factory default setting. Try performing a factory reset
on a Agility that is not being located.
• The Agility unit is not located in the same Ethernet segment as the iPATH Agility Controller. Double check connections and
move units where necessary, so that all reside within the same Ethernet segment.
• There is a potential cabling problem between the Agility and iPATH units. Check and where necessary, replace faulty cables.
4.3.4 Agility manual factory reset
Where a previously configured Agility unit is being added to a network for control by an iPATH Agility Controller, you can use this
method to reset the unit to its default configuration.
4.3.4.1 To perform a manual factory reset
1 Remove power from the Agility unit.
2 Use a narrow implement (e.g. a straightened-out paper clip) to press-and-hold the recessed reset button on the front panel.
With the reset button still pressed, re-apply power to the unit and then release the reset button.
Agility
After roughly eight seconds, when the factory reset has completed, five of the front panel indicators will flash for a period of
three seconds to indicate a successful reset operation.