Clearing Unused 16-Bit Interface Indexes; Disabling Password Recovery Capability - HP 5830 Series Configuration Manual

Hide thumbs Also See for 5830 Series:
Table of Contents

Advertisement

Step
1.
Enter system view.
2.
Configure temperature
thresholds for an IRF
member device.
Table 22
Default temperature thresholds
Switch model
HP
5830AF-48G(
JC691A)/ HP
5830AF-48G
TAA (JG316A)
HP
5830AF-96G(
JC694A) /HP
5830AF-96G
TAA(JG374A)

Clearing unused 16-bit interface indexes

The device must maintain persistent 16-bit interface indexes and keep one interface index match one
interface name for network management. After deleting a logical interface, the device retains its 16-bit
interface index so the same index can be assigned to the interface at interface re-creation.
To avoid index depletion causing interface creation failures, you can clear all 16-bit indexes that have
been assigned but not in use. The operation does not affect the interface indexes of the interfaces that
have been created but the indexes assigned to re-recreated interfaces might change.
A confirmation is required when you execute this command. The command will not run if you fail to make
a confirmation within 30 seconds or enter N to cancel the operation.
To clear unused 16-bit interface indexes, execute the following command in user view:
Task
Clear unused 16-bit interface indexes of all IRF
member devices

Disabling password recovery capability

Command
system-view
temperature-limit slot slot-number
hotspot sensor-number lowerlimit
warninglimit [ alarmlimit ]
Airflow
Sensor
direction
power-to-port
1-2
port-to-power
1-2
power-to-port
1-4
port-to-power
1-4
Remarks
N/A
Optional.
For the default temperature thresholds,
see the following table.
The warning and alarming thresholds
must be higher than the lower
temperature threshold.
The alarming threshold must be higher
than the warning threshold.
Lower
Warning
temperature
temperature
threshold
threshold
0°C (32°F)
70°C (158°F)
0°C (32°F)
80°C (176°F)
62°C
0°C (32°F)
(143.6°F)
62°C
0°C (32°F)
(143.6°F)
Command
reset unused porttag
133
Alarming
Shutdown
temperature
temperature
threshold
threshold
87°C
N/A
(188.6°F)
97°C
N/A
(206.6°F)
77°C
N/A
(170.6°F)
77°C
N/A
(170.6°F)

Hide quick links: