6 Using the product
Setting parameters
Parameter
Stability time
Measurement period
Test pressure (target) Set test pressure
1. Edit values: [Edit].
2. Enter values. [▲],
Carrying out repeated testing PS>0.5 bar
1. Build up test pressure (target) manually with the test pump or a
compressor at the connection provided.
2. Start measurement:
-
Zeroing starts (5 s)
Option
> End stability time early:
> End measurement period early:
-
-
Pressure test is ended.
3. Evaluate measurement result: [▲],
-
The measurement result is displayed
4 Save the measurement result: [Save].
Options
>
[Options]
values is displayed in a line graph (zoom function available [▲],
[▼]).
>
[Options]
in the same way.
>
[Options]
default settings.
>
[Options]
across the overall measuring time are displayed in a line graph.
54
Explanation
Set stability time
Set measurement period
[▼]
[
Measurement is cancelled.
Show
Graphic: a section of past measuring
→ Manometer: The measuring values are displayed
Factory
Overall graphic
TRF 2012 stipulates a
measurement period of 10 min.
According to TRF 2012, the test
pressure is 150 mbar.