Equipment   P Rovider   M Aintenance - CAIRE FreeStyle Provider Technical Service Manual

With ultrasense and patient-removable battery
Hide thumbs Also See for FreeStyle:
Table of Contents

Advertisement

 
 
 
EQUIPMENT   P ROVIDER   M AINTENANCE  
NO   S CHEDULED   M AINTENANCE  
FreeStyle   a nd   F reeStyle   5   u nits   a re   m aintenance-­‐free   d ue   t o   t heir   t echnologically   a dvanced  
design.   C AIRE   d oes   n ot   r equire   p reventative   m aintenance   o r   s ervice   o n   t hese   c oncentrators   a s  
long   a s   t he   c oncentrator   r emains   w ithin   s pecifications.   T o   e nsure   t hat   t he   u nit's   o utput   o f  
oxygen   i s   w ithin   s pecification,   y ou   m ust   e stablish   a nd   i mplement   a   p rotocol   t o   c heck   o xygen  
concentration   u pon   d elivery   t o   a   p atient   a nd   a t   p eriodic   i ntervals   ( Reference   O XYGEN  
CONCENTRATION   T EST   s ection   o f   t his   m anual).  
 
AIR   I NTAKE   /   G ROSS   P ARTICLE   F ILTER  
The   e xternal   a ir   i ntake   g ross   p article   f ilter   i s   l ocated   i n   t he   a ir   i ntake/filter   c over.   Y ou   c an   e asily  
remove   i t   b y   h and.   I nstruct   t he   p atient   t o   c lean   t his   f ilter   w eekly.   ( Reference   C LEANING   T HE   A IR  
INTAKE   /   G ROSS   P ARTICLE   F ILTER   s ection   o f   t his   m anual).  
 
 
 
The   f ilter   m ay   r equire   m ore   f requent   c leaning   i f   t he   u nit   o perates   i n   a   h arsh  
environment   –   a   h ouse   h eated   b y   w ood,   k erosene,   o r   o il,   o r   o ne   w ith   e xcessive  
cooking   o r   c igarette   s moke.  
 
 
 
Turn   O FF   t he   u nit   a nd   d isconnect   t he   p ower   c ord   f rom   t he   e lectrical  
outlet   b efore   y ou   c lean   t he   u nit   t o   p revent   a ccidental   e lectrical   s hock  
and   b urn   h azard.    
 
 
Remove   t he   b attery   f rom   t he   u nit   b efore   p erforming   a ny   m aintenance   t o  
prevent   a ccidental   e lectrical   s hock   a nd   b urn   h azard.  
 
 
 
The   F reeStyle   o r   F reeStyle   5   m ust   b e   o ff   a nd   d isconnected   f rom   e xternal   p ower  
before   r emoving   t he   b attery   p ack.  
 
 
PRODUCT   F ILTER   R EPLACEMENT  
The   p roduct   f ilter   i s   d esigned   t o   l ast   t he   l ife   o f   t he   u nit.   I f   i t   i s   d etermined   t hat   t he   p roduct   f ilter  
needs   t o   b e   r eplaced,   f ollow   t he   i nstructions   b elow:
 
Portable   O xygen   C oncentrator    
 
 