Applications
Application
One Gear Drive (OGD) LA10.
Parameter 0-16 Application Selection is set to [6] OGD LA10.
Description
For applications that use OGD. For example, conveyors in food
and beverage industries.
FC 360
+24V 12
DI1
18
Start
DI2
19
DI3
27
Coast inverse
DI4
29
DI5
3
1
DI6
3
2
DI7
3
3
COM 20
+10V 50
4-20
AI1
53
mA
-
+
54
AI2
COM 55
AO1
42
AO2
45
1
2
R1
3
4
5
R2
6
Parameter settings
Parameter
Parameter 1-00 Configuration Mode
Parameter 1-01 Motor Control Principle
Parameter 1-08 Motor Control Bandwidth
Parameter 1-10 Motor Construction
Parameter 1-14 Damping Gain
Parameter 1-15 Low Speed Filter Time
Const.
Parameter 1-16 High Speed Filter Time
Const.
Parameter 1-17 Voltage filter time const.
Parameter 1-24 Motor Current
Parameter 1-25 Motor Nominal Speed
Parameter 1-26 Motor Cont. Rated Torque
Parameter 1-29 Automatic Motor
Adaptation (AMA)
Parameter 1-30 Stator Resistance (Rs)
Parameter 1-37 d-axis Inductance (Ld)
Parameter 1-39 Motor Poles
Parameter 1-40 Back EMF at 1000 RPM
Parameter 1-42 Motor Cable Length
Parameter 1-66 Min. Current at Low Speed 50
Parameter 1-73 Flying Start
Parameter 2-06 Parking Current
MG06A702
Quick Guide
Parameter 2-07 Parking Time
Parameter 2-10 Brake Function
Parameter 3-03 Maximum Reference
Parameter 4-14 Motor Speed High Limit
[Hz]
Parameter 4-16 Torque Limit Motor Mode
Parameter 4-18 Current Limit
Parameter 5-10 Terminal 18 Digital Input
Parameter 5-11 Terminal 19 Digital Input
Parameter 5-12 Terminal 27 Digital Input
Parameter 5-13 Terminal 29 Digital Input
Parameter 5-14 Terminal 32 Digital Input
Parameter 5-15 Terminal 33 Digital Input
Parameter 5-16 Terminal 31 Digital Input
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-14 Terminal 53 Low Ref./
Feedb. Value
Parameter 6-15 Terminal 53 High Ref./
Feedb. Value
Parameter 6-19 Terminal 53 mode
Parameter 14-01 Switching Frequency
Parameter 14-07 Dead Time Compen-
sation Level
Parameter 14-64 Dead Time Compen-
sation Zero Current Level
Parameter 14-65 Speed Derate Dead Time
Compensation
Parameter 14-51 DC-Link Voltage Compen-
sation
Parameter 30-20 High Starting Torque
Option/value
Time [s]
[0] Open Loop
Parameter 30-21 High Starting Torque
[1] VVC+
Current [%]
High
Parameter 30-22 Locked Rotor Protection
[1] PM, non-salient SPM
Parameter 30-23 Locked Rotor Detection
120
Time [s]
0.175
Table 6.6 One Gear Drive (OGD) LA10
0.175
0.035
7.2
3000
12.6
[0] Off
0.5
5
10
120
50 m
[2] Enable always
80
Danfoss A/S © 03/2017 All rights reserved.
0.5
[0] Off
250 Hz
250 Hz
160
160
[8] Start
[0] No operation
[2] Coast inverse
[0] No operation
[0] No operation
[0] No operation
[0] No operation
6
4.0 mA
20.0 mA
0
250
[0] Current Mode
10.0 kHz
65
[0] Disabled
250
[0] Off
0
100
[0] Off
1
41
6
Need help?
Do you have a question about the VLT AutomationDrive FC 360 and is the answer not in the manual?
Questions and answers