Applications
Application
Conveyors, extruders.
Parameter 0-16 Application Selection is set to [3] Speed Open Loop.
Description
For running at a stable speed by a voltage reference signal.
FC 360
+24V 12
DI1
18
Start
DI2
19
DI3
27
Coast inverse
DI4
29
DI5
3
1
DI6
3
2
DI7
3
3
COM 20
+10V 50
AI1
53
54
AI2
COM 55
AO1 4
2
AO2 4
5
1
2
R1
3
4
5
R2
6
Parameter settings
Parameter
Parameter 1-00 Configuration Mode
Parameter 3-00 Reference Range
Parameter 3-15 Reference 1 Source
Parameter 4-12 Motor Speed Low Limit
[Hz]
Parameter 4-14 Motor Speed High Limit
[Hz]
Parameter 5-10 Terminal 18 Digital Input
Parameter 5-12 Terminal 27 Digital Input
Parameter 5-40 Function Relay (Relay 1
Selection)
Parameter 5-40 Function Relay (Relay 2
Selection)
Parameter 6-10 Terminal 53 Low Voltage
Parameter 6-11 Terminal 53 High Voltage
Parameter 6-19 Terminal 53 mode
Parameter 6-70 Terminal 45 Mode
Parameter 6-71 Terminal 45 Analog
Output
Parameter 6-90 Terminal 42 Mode
Parameter 6-91 Terminal 42 Analog
Output
Table 6.3 Speed Open Loop
MG06A702
Quick Guide
Application
Machine tools, texturizers.
Parameter 0-16 Application Selection is set to [4] Simple Speed
Closed Loop.
Description
For precise speed applications with 24 V encoder feedback.
+24 V 12
COM 20
+10 V
COM 55
Parameter settings
Option/value
Parameter
[0] Speed Open Loop
Parameter 1-00 Configuration Mode
[0] Min–Max
Parameter 3-00 Reference Range
[1] AI 53
Parameter 3-15 Reference 1 Source
25.0 Hz
Parameter 3-16 Reference 2 Source
50.0 Hz
Parameter 4-12 Motor Speed Low Limit
[Hz]
[8] Start
Parameter 4-14 Motor Speed High Limit
[Hz]
[2] Coast Inverse
Parameter 5-10 Terminal 18 Digital Input
[5] Running
Parameter 5-12 Terminal 27 Digital Input
[9] Alarm
Parameter 5-14 Terminal 32 Digital Input
Parameter 5-15 Terminal 33 Digital Input
0.07 V
Parameter 5-40 Function Relay (Relay 1
10 V
Selection)
[1] Voltage Mode
Parameter 5-40 Function Relay (Relay 2
Selection)
[0] 0–20 mA
Parameter 6-10 Terminal 53 Low Voltage
[100] Output frequency
Parameter 6-11 Terminal 53 High Voltage
[0] 0–20 mA
Parameter 6-19 Terminal 53 mode
[103] Motor Current
Parameter 6-70 Terminal 45 Mode
Parameter 6-71 Terminal 45 Analog
Output
Parameter 6-90 Terminal 42 Mode
Danfoss A/S © 03/2017 All rights reserved.
FC 360
DI1
18
Start
DI2
19
DI3
27
DI4
29
Coast inverse
DI5
3
1
DI6
3
2
B
DI7
3
3
A
50
AI1
53
54
AI2
AO1 4
2
AO2 4
5
1
2
R1
3
4
5
R2
6
6
Option/value
[1] Speed Close Loop
[0] Min–Max
[1] AI 53
[11] Local Bus Ref
20.0 Hz
50.0 Hz
[8] Start
[2] Coast Inverse
[82] Encoder input B
[81] Encoder input A
[5] Running
[9] Alarm
0.07 V
10 V
[1] Voltage Mode
[0] 0–20 mA
[100] Output frequency
[0] 0–20 mA
39
6