The power/Ethernet cable runs from inside the building to the CSM. The following procedure
describes how to run the cables through the wall of the building.
CAUTION
Procedure 6-9
1
2
3
4
PMP320HDW2v1
Observe caution when drilling through the wall of the building. Ensure that there are
no power lines, gas lines, water lines, or data lines in the wall at the desired location
where the drilling takes place.
Running cables through the wall of the building
CAUTION
Follow local building codes for penetrating buildings. Observe
caution when drilling through the wall of the building. Ensure that
there are no power lines, gas lines, water lines, or data lines in
the wall at the desired location.
Drill a 3/4 inch. (18 mm) hole through the wall at the desired location.
Draw one end of the category 5e cable through the hole.
Route the category 5e power/Ethernet cable from the surge suppressor to the
location where the power supply is to be plugged in.
After completing the installation, use a grommet for the hole and seal the hole
with a silicone or acrylic caulking material.
Running cables through the wall of the building
Preliminary
6-15