1
Ensure that the mounting position:
Select a support structure to which the flanges can be mounted.
2
If the support structure is:
3
If the CMM4 is mounted to a non-conducting structure (cinder block wall, for
4
example) or there is any doubt as to a good ground through the structure,
run a 10 AWG ground cable from one of the Ground/Earth terminations of
one of the terminal blocks inside the CMM4, through a cable gland, and to
known good ground.
3-40
Installing the CMM4
is not
farther than 328 feet (100 meters) from the furthest AP or BH
that the CMM4 will serve.
is not
closer than 10 feet (3 meters) to the nearest AP or BH.
is not
further than 100 feet (30.5 meters) of cable from the intended
mounting position of the GPS antenna.
allows the doors to open fully open for service.
a wall, use screws or bolts (neither is provided) to attach the flanges
to the wall.
an irregular-shaped object, use adjustable stainless steel bands
(provided) to attach the CMM4 to the object.
a pole that has an outside diameter of 1.25 to 3 inches (3 to 8 cm), use a
toothed V-bracket (provided) to attach the V-bracket to the pole. Then
attach the CMM4 flanges to the V-bracket.