Error Code
Reply
Seriousness
Keys
-120
OK
Error
-122
OK
Error
0xeff3, 0xeff4
Error Code List for Version 6.00
[Operation after Reply Key is touched]
#1:Error
#2:Sensor Unit: SelfCheck Error
#3:Detected an Error.
#4:ER(n) (xxxx)
n: Sensor Index (1 to 4)
xxxx: Error code
[Cause]
An undefined error has been found in the sensor A/D board.
[Operation after Reply Key is touched]
Nothing
#1:Error
#2:Sensor Unit:Control Error
#3:Detected Control Error. Call a service person.
[Cause]
An error in the control line has been detected in the sensor
A/D board.
[Operation after Reply Key is touched]
When OK key is touched, the sensor will be disconnected.
(Access will not be made, as the system is in an "abnormal"
state.)
A service person needs to be called in.
"Sensor Unit – Power Box(n)(eff3 or eff4)"
0xeff3: There might be problems in the setting of the cable
length (Sensor Power Box and X-ray board cable).
0xeff4: There might be problem that Sensor Power cable is
broken.
n: Sensor Index (1 to 4)
- 6 -