9.2.1
ON
If ON is selected, the zone requests are met.
9.2.2
AUTO
If AUTO is selected, the zone requests will be managed based on a
scheduled programme.
9.2.3
MANUAL
If MANUAL is selected, the zone requests will be managed based on the
setpoint set by the user.
9.2.4
HEAT OFF
If HEAT OFF is selected, the zone requests will not be fulfilled.
NOTE: if you want to deactivate the zone in SUMMER or in WINTER,
you must select the pre-set season (SUMMER or WINTER in the BOILER
menu) and set the zone concerned to OFF.
10 SET
With the
function it is possible to configure the
SET
WATER
setpoints.
To do this, it is necessary to highlight the desired entry using the "up" and
"down" keys and then pressing "ok" to confirm the selection.
Pressing "back" takes you back to the initial screen without making any
selection.
10.1 Heating
Press the "up" and "down" keys to change the heating setpoint and
confirm the selection by pressing "ok".
Press "back" to return to the SET screen without making any selection.
78,0
When an outdoor temperature sensor is installed, the outlet temperature
is automatically selected by the system, which quickly adjusts the ambient
temperature according to the variations in the outdoor temperature. If you
want to change the temperature, raising it or lowering it with respect to that
automatically calculated by the electronic board, it is possible to change
the HEATING setpoint selecting the desired comfort level within the range
(-5 ÷ +5).
The user is then asked to confirm the setpoint setting: select CONFIRM
or CANCEL using the "up" and "down" keys, and confirm the selection
pressing "ok" .
Once the selection is confirmed, the display returns to the SET screen.
If the selection is cancelled or the "back" key is pressed you return to the
previous SET screen.
THE PARAMETER
WILL BE CHANGED
CONFIRM
CONFIRM OR DELETE
30
HEATING
SET
HEATING
HOT WATER
SET
HEATING
°C
SET
CANCEL
SELECTION
10.2 Domestic hot water (only when storage tank with
probe is connected)
Press the "up" and "down" keys to change the boiler's domestic hot water
setpoint. Press "ok" to confirm the selection.
Press "back" to return to the
The user is then asked to confirm the setpoint setting: select CONFIRM
and
HOT
or else
CANCEL
confirmation with "ok".
Once the selection is confirmed, the display returns to the previous
screen.
If the selection is cancelled or the "back" key is pressed you return to the
screen.
SET
11 INFO
The INFO function can be used to display a series of data regarding the
system.
ATTENTION - The displayed data cannot be modified.
Press the "up" and "down" keys to go through the list of information
available, in this order:
- SCREED HEATER OPERATING HOURS
- FLOW PROBE
- RETURN PROBE
- DOMESTIC HOT WATER PROBE
- FLUE GAS PROBE
- OUTDOOR TEMPERATURE SENSOR
- EXT T FOR THERMOREG
- FAN
- ZONE 1 DELIVERY
- ZONE 2 DELIVERY
- FLUE GAS PROBE OP. HOURS
- MAIN ZONE SET-POINT
- ZONE 1 SET-POINT
- ZONE 2 SET-POINT
- SYSTEM PRESSURE.
The "ok" key is inactive.
The "back" key allows you to return to the initial screen.
In the absence of additional zones or if the screed heater function is not
operating, the relative information will not be displayed.
12 MENU
Using the MENU it is possible to access the configuration of the SETTINGS
and the TIME SCHEDULE (available only if the timer is enabled (POR=1).
To do this, it is necessary to highlight the desired entry using the "up" and
"down" keys and then pressing "ok" to confirm the selection.
Pressing "back" takes you back to the initial screen without making any
selection.
screen without making any selection.
SET
SET
HOT WATER
58,0
°C
using the "up" and "down" keys and confirm the
SET
THE PARAMETER
WILL BE CHANGED
CONFIRM
CANCEL
CONFIRM OR DELETE
SELECTION
SET