HOT WATER TEMPERATURE
- Through the REC10 it is possible to access, using the TECHNICAL
menu, a series of parameters that can be programmed to allow you to
personalise the operation of the boiler based on the type of system.
- Then set the parameters according to the desired operating modes.
5.2.1

Boiler configuration

- Access the technical parameters as explained in the section "4.1 Access
to the technical parameters" .
- Select PARAMETERS with the "up" and "down" keys, confirming the
selection.
INSTALLATION
PARAMETERS
TERMOREGOLAZIONE
THERMOREGULATION
RANGE RATED
CALIBRATION
INSTALLER
-
Select from among the following options with the "up" and "down",
keys, confirming the selection.
14
PLANT
12:17
1.3 bar
STATE
42
°C
SET
STATE
BOILER
MAIN ZONE
BOILER
OFF
SUMMER
WINTER
TECHNICAL
PARAMETERS
TIMER OFF CH
RESET TIMERS CH
DHW THERMOSTAT
INSTALLER
- TIMER OFF CH
This parameter allows you to change the TIMER OFF CH, regarding
the delay time introduced for re-igniting the burner in the face of an off
due to the heating temperature being reached. The factory setting for
this parameter is 3 minutes and can be set to a value between 0 min
and 20 min selecting the desired one with the "up" and "down", keys
confirming the selection.
TIMER OFF CH
-
RESET TIMERS CH
This parameter allows you to reset the REDUCED HEATING MAXIMUM
OUTPUT TIMING, during which the speed of the fan is limited to 75%
of the maximum heating output that has been set, and the TIMER OFF
CH. The factory setting for this parameter is FUNCTION NON ACTIVE,
select FUNCTION ACTIVE using the keys "up" and "down", confirming
the selection for resetting the timings.
RESET TIMERS CH
FUNCTION NOT ACTIVE
FUNCTION ACTIVE
INSTALLER
- SLIDING OUTLET (only if storage tank connected)
This parameter allows activating the SLIDING OUTLET function to modify
the outlet setpoint used by the boiler when receiving a DHW request. The
factory setting for this parameter is FUNCTION NON ACTIVE; this setting
performs a modulation to a fixed outlet value of 80°C in case of DHW
request. Select FUNCTION ACTIVE using the keys "up" and "down",
confirming the selection. In this case, the outlet setpoint in DHW request
is no longer fixed at 80°C but variable, and it is calculated automatically
by the boiler based on the difference between the desired DHW setpoint
and the temperature value detected by the storage tank probe.
Note: we do not recommend activating this function for storage tanks with
a capacity of over 100 litres since the storage tank filling would be too
slow.
Attention: it may be necessary to set the value of this parameter again
after replacing the setting board.
SLIDING OUTLET
FUNCTION NOT ACTIVE
FUNCTION ACTIVE
INSTALLER
3