Installation And Control Panel Wiring (Keyswitches); Radion Keyfobs And Inovonics Pendant Transmitters - Bosch B6512 Installation Manual

Hide thumbs Also See for B6512:
Table of Contents

Advertisement

48
en | Keypads, keyswitches, keyfobs and transmitters
9.2.2

Installation and control panel wiring (keyswitches)

For maintained switches, connect the EOL resistor for the point at the keyswitch so that the
switch opens the circuit when it operates. A short on the circuit produces an alarm if the area
is armed and a trouble if it is disarmed.
For momentary keyswitches, connect the EOL resistor at the keyswitch point so that when the
keyswitch operates, it shorts the resistor. An open on the circuit causes an alarm if the area is
on (armed) and a trouble if it is off (disarmed).
Figure 9.3: Keyswitch wiring
Callout ᅳ Description
1 ᅳ Maintained keyswitch
2 ᅳ Momentary keyswitch
3 ᅳ Common
4 ᅳ Point input
Keyswitches are not intended for use in UL listed systems.
9.3

RADION keyfobs and Inovonics pendant transmitters

The control panel supports one RADION keyfob or one Inovonics pendant transmitter for each
user the control panel supports.
The control panel supports two RADION keyfob models, RFKF-FB-A and RFKF-TB-A, that
communicate with the control panel using the B810 wireless receiver.
RADION keyfob FB
The RADION keyfob FB four button keyfobs are designed for arming (lock icon) and disarming
(unlock icon) the system remotely. You can configure the programmable buttons at the control
panel for additional control functionality. To operate the programmable buttons, simply press
and hold either button for at least one sec in order for the desired feature to work.
2017.04 | 15 | F.01U.287.180
1
3
5
4
B6512. Up to 10 wireless RADION keyfobs or 100 Inovonics pendant transmitters.
B5512. Up to 50 wireless RADION keyfobs or 50 Inovonics pendant transmitters.
B4512. Up to 32 wireless RADION keyfobs or 32 Inovonics pendant transmitters.
B3512. Up to 10 wireless RADION keyfobs or 10 Inovonics pendant transmitters.
Uniquely coded arm and disarm buttons
Panic alarm
LED indicator
Programmable option buttons
6
Callout ᅳ Description
5 ᅳ EOL (End of Line) resistor
6 ᅳ Open on the circuit arms the area
7 ᅳ Momentary short on the circuit toggles
the arming state