B426 Ethernet Communication Module

The B426 Conettix Ethernet Communication Module is a four-wire powered SDI2 device that
provides connection for two-way communication over Ethernet networks to the control panels.
The control panel supports one module.
The B426 Conettix Ethernet Communication Module connects to the SDI2 bus on the control
panel using the SDI2 terminals, or using the SDI2 interconnect wiring connector. This section
includes basic installation instructions. For detailed installation instructions, refer to the
Conettix Ethernet Communication Module (B426) Installation and Operation Guide (P/N:
F01U281208).
8.3.1

Address and emulation settings

Notice!
The module reads the address switch setting only during module power up. If you change the
setting after you apply power to the module, you must cycle the power to the module in order
for the new setting to take effect.
Set the address switch to 1.
8.3.2

Supervision

The control panel supervises in two ways:
8.3.3

B426 module faults

With a B426 installed, several services become available to the control panel. Any break in the
Ethernet connection to a supervised B426 results in a system fault at the keypads indicating
Open Cable trouble.
If a Domain Name Server (DNS) is available on the network, a failure to resolve an individual
Network Address hostname results in a system fault at the keypads indicating DNS ERROR ##.
The error number represents the communication module and destination combination that
2017.04 | 15 | F.01U.287.180
Off
Module supervision. The control panel supervises the module through polling. If the
module does not respond to the control panel polling, the control panel declares the
device missing.
Communication supervision. The control panel supervises the communication path by
polling the central station receiver. If the poll is missed from either side, a communication
fault is declared both at the control panel and the central station receiver.
Function
Normal state. Indicates normal operation.
Flashes
Communication error state. Indicates the
module is unable to communicate on the
cellular network.
LED trouble state. Module is not powered, or
some other trouble condition prohibits the
module from controlling the heartbeat LED.