Trigger Mode; Trigger Source; Trigger Activation - Smartek UCC User Manual

Twentynine camera family
Table of Contents

Advertisement

Value
AcquisitionStart
FrameStart
FrameBurstStart

5.4.2.2 Trigger Mode

Selected trigger can be enabled or disabled via the TriggerMode property.
Value
On
Off

5.4.2.3 Trigger Source

The TriggerSource property specifies the internal signal or physical input line to use as the trigger
source. The selected trigger must have its TriggerMode set to On . Possible values for the TriggerSource
are shown in Table 33.
Value
Line1
Software

5.4.2.4 Trigger Activation

For some trigger sources it is possible to define the activation mode of the trigger. Possible values
are presented in Table 34.
Value
RisingEdge
FallingEdge
A trigger that starts the acquisition of one or many frames according to
A trigger starting the capture of one frame
A trigger starting the capture of the burst of frames in an acquisition.
AcquisitionBurstFrameCount controls the length of each burst. The total number of
frames captured is also conditioned by AcquisitionFrameCount when
Table 31: Supported Trigger types
Table 32: Trigger Mode
Specifies that the physical Input Line1 will be used as an external source for the
Specifies that the trigger source will be generated by software using the
Table 33: Trigger Sources
Specifies that the trigger is considered valid on the rising edge of the source signal
Specifies that the trigger is considered valid on the falling edge of the source signal
Table 34: Trigger Activation modes
Description
AcquisitionMode
AcquisitionMode is MultiFrame .
Description
Enables the selected trigger
Disables the selected trigger
Description
trigger signal
TriggerSoftware command
Description
61
User Manual - twentynine
SMARTEK Vision | User Manual - twentynine | Doc. v1.0.2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gcc