Elcometer 224 Operating Instructions Manual page 26

Model t surface profile gauge
Hide thumbs Also See for 224:
Table of Contents

Advertisement

The Elcometer 224 then asks the user to set the counted average
value. Using the up and down arrow softkeys, set the counted
average from 2 - 99 and press the Ok softkey.
This returns the user to the previous screen. Press the Back
softkey to continue setting up the new batch as required before
opening the new batch.
If Statistics are displayed whilst measuring using the counted
average function (CAF) when taking the readings used to calculate
the CAF measurement, the gauge will display the rolling statistical
calculations of the individual readings until all the readings that go
into calculating the CAF measurement are taken. At this point the
statistics then display the values of the stored CAF measurements.
Note: The batch type can only be changed when creating a new batch.
Fixed Batch Size
When creating a new batch, by selecting Batch/New Batch and
checking the Fixed Batch Size radio button, users can pre-define the
number of readings that are to be stored into the batch using the up
and down arrow softkeys.
Once the batch has been opened and readings are being taken, the
Elcometer 224 will notify the user when the fixed batch size is
complete and ask if another batch is to be opened.
If the user selects No, then the gauge closes the batch and exits
batching - returning the gauge to the Immediate mode. If the user
selects Yes, then the gauge automatically:
Appends a '_1' to the original batch name
Opens a new batch - copying all the batch setup and calibration
information
The new batch is named as the original batch, with a '_2'
For example:
A fixed batch is created and named "Component A".
When the batch is full, a new fixed batch 'Component A_2' is
created
'Component A' becomes 'Component A_1'
25