15-8.

Removing the ventilation fan motor (M6)

4131D012AA
15-9.

Removing the left-side cover

4131D011AA

15-10. Removing the power unit (PU)

4131D013AA
4131D014AB
1. Open the right-side door.
2. Remove the top-front cover, top cover and the rear
cover.
3. Unplug connector PJ6 from the master board
(PWB-A), and then remove the wiring from the
cable holders.
4. Remove the ventilation fan motor. (2 screws)
1. Open the right-side door.
2. Remove the top-front cover and the top cover.
3. Remove the left-side cover. (3 screws)
1. Open the right-side door.
2. Remove the top-front cover, top cover and the left-
side cover.
3. Remove the protective cover. (3 screws)
4. Remove the wiring from the 3 cable holders.
5. Remove the power unit. (3 screws, 5 connectors
and 3 holders)