Pre-Installation Information

This chapter describes items to check when inspecting the installation site and the
grounding and power conditions before installing the OfficeServ 7200 system.
This chapter also describes the items included in the OfficeServ 7200 package and
the installation procedure.
1

Location Conditions

Select a location that satisfies the following conditions for safety, temperature and
humidity:
1.1

Safety Conditions

The OfficeServ 7200 system should not be installed near materials that can cause a
fire, such as explosive gas and inflammables. The OfficeServ 7200 system should
not be near equipments that generate electromagnetic waves, such as monitors or
copying machines.
The installation location should be convenient for distributing trunk lines and
extension lines, for connecting power and grounding wires, and for maintenance
and repair.
The OfficeServ 7200 system should not be installed in aisles or passageways that
are populated or used for moving equipment.
Always maintain cleanliness to prevent dust from damaging the Module-
connecting part of the Chassis.
Before installing the OfficeServ 7200 system, check items such as the electrical
wiring status, grounding status, voltage and frequency.
1.2

Temperature/Humidity Conditions

The conditions for temperature and humidity are as follows:
Operation temperature : 0~45 °C
Storage temperature : -10~+50 °C
Humidity : 10~90 %