Starting the System

The procedure for starting the OfficeServ 7200 system is as follows:
1) Check if the Modules and cables are properly mounted and connected to the
OfficeServ 7200 Chassis.
2) Turn on the power of the OfficeServ 7200 basic Chassis, and turn on the power
of the expansion Chassis.
3) Check the LEDs of the MCP and LCP Modules.
The RUN LED of the MCP Module lights green and the SM LED flashes when
the system normally starts the booting process.
Once the booting is complete, the RUN LED of the MCP Module flashes green,
and the SM LED stops flashing and remains lighted.
The RUN LED of the LCP Module flashes when the power supply and processor
status of the expansion rack is normal.
4) Check if the LED statuses of other interface Modules are normal.
5) If the LED status of a MCP, LCP, or interface Module is abnormal, turn off the
power of the Chassis and turn the power on again.
© SAMSUNG Electronics Co., Ltd.
If the Smart Media is not detected
If the system cannot detect the smart media, the SM LED of the MCP Module might
not light or flash. In such cases, turn off the power of the basic Chassis, replace the
smart media and turn the power on again. If the smart media is still not detected,
turn off the power of the basic Chassis and eject the MCP Module.
LED Status & Shut-down
- Refer to the 'OfficeServ 7200 General Description Guide' for LED statuses of each
Module.
- Shut-down is hardly required while operating the OfficeServ 7200 system.
However, when shutting down the system due to reasons such as moving the
system, turn off the power of the expansion Chassis, and turn off the power of the
basic Chassis.
CHAPTER 8. Starting the System