Mounting Control Modules; Setting Switches And Mounting Optional Modules; Figure 3.3 Switch Setting; Table 3.3 Switches - Samsung OfficeServ 7200 Installation Manual

Hide thumbs Also See for OfficeServ 7200:
Table of Contents

Advertisement

CHAPTER 3. Mounting and Replacing Modules
2

Mounting Control Modules

This section describes the procedures for setting switches, mounting optional
Modules, mounting the Modules on a slot, and how to connect between the MCP
and LCP Modules.
2.1

Setting Switches and Mounting Optional Modules

The MCP Module features switches used for optimizing the Module to the user
requirements and system configuration. The procedure for setting switches and
mounting optional Modules is as follows:
1) Set the S2 switch to On and set the SW1 through SW4 of the S3 switch to Off.
Set the SW6 through SW8 of the S3 switch according to user requirements.
Switch
S2
For memory backup, set to On before mounting on each slot
S3
SW1~SW4
SW6~SW8
Page 3-4
S3

Figure 3.3 Switch Setting

Table 3.3 Switches

Description for setting switches
Sets country option.
Sets the number of digits for C.O./extension lines and extension
groups.
SW6-On : 4 digits for C.O. line Off : 3 digits for C.O. line
SW7-On : 4 digits for an extension group Off : 3 digits for an
extension group
SW8-On : 4 digits for an extension number Off : 3 digits for an
extension number
OfficeServ 7200 Installation guide/Ed.00
S2
CHARGE
Off
© SAMSUNG Electronics Co., Ltd.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents