Warning Messages - Xantrex Freedom HF 1000 Owner's Manual

Inverter/charger
Hide thumbs Also See for Freedom HF 1000:
Table of Contents

Advertisement

Warning Messages

Table 5-1 Error Codes Displayed on the Display Panel Screen
Error Code Condition
E01
Low battery voltage
shutdown
(< 10.5 Vdc)
E02
High battery voltage
shutdown
(> 15.5 Vdc)
E03
AC output overload
shutdown
E04
Over-temperature
shutdown
E05
Low battery voltage
detected
(< 11.0 Vdc)
E06
AC output overload
warning
975-0390-01-01
Warning messages in the form of audible alarms and error codes that
appear on the display panel screen to alert you to an impending system
change. Warnings do not affect operation.
With the exception of the error codes displayed on the screen, only the
audible alarm can be turned ON or OFF. Follow the steps in
"To adjust the alarm setting:"
The error codes are listed in
column appears on the display screen of the display panel.
Mode
Inverting
Inverting
Inverting
Inverting
Inverting
Inverting
on
page 3–5
to change the alarm settings.
Table 5-1
below. The text in the Error Code
Action
Check battery status and recharge if
necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if
necessary.
Check for external charging sources, such
as an over voltage alternator, and
disconnect if necessary.
Reduce the loads connected to the AC
outlet of the unit.
Check appliances that have high-surge
ratings and disconnect if necessary.
Reduce the loads connected to the AC
outlet of the unit.
Check that the ventilation grille is not
blocked.
Check for ambient temperature and move
the unit to a cooler location whenever
possible.
Check battery status and recharge if
necessary.
Check for proper DC cable sizing.
Check for loose connections and tighten if
necessary.
Reduce the loads connected to the AC
outlet of the unit.
Warning Messages