Electrical Specifications: Inverter Mode

DC Input
Operating voltage range
Safe non-operating voltage range
Normal voltage
Nominal current at full load
AC Output
Output voltage
Continuous power
Surge power
Max short-circuit current
Frequency
Wave shape
Power derating above 40 °C ambient
temp
Peak efficiency
Full load efficiency
Other
No load input power (producing
output voltage)
Off mode current draw
A–2
Freedom HF 1000
10.5V–15.5V
0–16 Vdc
12.5V
100A
Freedom HF 1000
115 Vac
1.0kW @ 25 °C
17A
(2kW for 200 ms)
55A peak
60 Hz
Modified Sinewave
See
"Invert Power Derating vs. Ambient
Temperature" on page
≥87%
≥80%
Freedom HF 1000
≤10W
≤1mA
Freedom HF 1800
10.5V–15.5V
0–16 Vdc
12.5V
180A
Freedom HF 1800
115 Vac
1.8kW @ 25 °C
30A
(3.6kW for 300 ms)
55A peak
60 Hz
Modified Sinewave
A–6.
≥87%
≥80%
Freedom HF 1800
≤10W
≤1mA
975-0390-01-01