Operating in Shore Power Mode

975-0390-01-01
The
Freedom HF
operates in shore power mode when an AC source (a
generator or utility power) is present at the AC input terminals. When the
AC source is within operating range, the
inverter function and powers the appliances connected to the unit. See
"Transitioning from Inverter Mode to Shore Power" on page
The
Freedom HF
also automatically charges the battery bank that is
connected while in shore power mode. See
page
4–11.
The Green status LED lights up to indicate that the
utility (or generator) power and the battery is full. A flashing Green LED
indicates that the unit is charging the battery.
When shore power is present, AC power will automatically pass through
the
Freedom
HF. Pressing the Inverter button on the display panel will not
interrupt the supply of shore power. Shore Power mode supersedes
Inverter mode.
When the
Freedom HF
is outside the operating range or is disconnected, the transfer switch
automatically switches to inverter mode. See
Power to Inverter Mode" on page
Freedom HF
's Inverter button is turned ON and the AC source
4–7.
Operating in Shore Power Mode
unit bypasses
4–7.
"Battery Charging" on
Freedom HF
"Transitioning from Shore
is using