Remote Services; Modes Of Operation; Ecp Mode; Zone Trigger Mode - Honeywell AlarmNet 7847i-E Installation And Setup Manual

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents

Advertisement

Remote Services

U L
Remote Access and Multi-Mode have not been evaluated by UL.
Honeywell now offers a new series of web based services that provides consumers with the
ability to communicate with their security system remotely in a number of ways. These new
web services will allow users to:
Access their security system from a computer via a website (Remote Access feature)
Receive email and text message notifications of system events (Multi-Mode feature)
Perform system functions and receive confirmations using text messages (SMS feature)
Dealers will initially enroll their customers for web services during account programming
through the AlarmNet Direct website. The features that can be enabled include Remote
Access and Multi-Mode. Once enabled, the specific programming fields associated with these
features can be programmed into the communications device either remotely using the
AlarmNet Direct website or locally using the 7720P local keypad programming tool.

Modes of Operation

The 7847i and 7847i-E provide four modes of operation so they can be used with various
types of control panels, as summarized below:

ECP Mode

This mode is for use with Honeywell controls that support LRR-ECP communication
The module connects to the control's keypad terminals and provides 2-way communication with
the control using ECP messaging
The control treats the module as a Long Range Radio (LRR) device, so program the control
accordingly, including setting the module's proper LRR device address
Panel-generated reports are sent in Contact ID format
The module also supports two hardwire zone trigger inputs (zones 6 and 7) – these report in
Ademco High-Speed format

Zone Trigger Mode

This mode is for use with controls that do not support LRR-ECP communication nor 4204 Relay
Modules
The module provides six input zones
Each zone can be configured for +V, -V, or EOLR triggering
Each zone can be programmed for inverted operation, delayed reporting, and restoral reporting
Zone 1 and 2 inputs can distinguish between pulsed and steady signals and report fire or burglary
alarms respectively
Zone 1 and 2 inputs can also be programmed to report LYNX panic (if used with LYNX control)
Reports are sent in ADEMCO High-Speed format

4204 Mode and Two-4204 Mode

This mode is for use with Honeywell controls that do not support LRR-ECP communication, but
that do support 4204 Relay Modules
The module connects to the control's keypad terminals
The control treats the module as 4204 Relay Module(s), so program the control accordingly,
including setting the module's proper 4204 device address
4204 mode provides up to four zone inputs, plus two optional trigger zones, depending on options
programmed
Two-4204 mode provides up to eight zone inputs, depending on options programmed
Section 1: General Information
1-3