Honeywell AlarmNet 7847i-E Installation And Setup Manual page 27

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents

Advertisement

PROMPTS
Verify Inst. Key:
19
**********_
Account information is provided by the central station administrator.
Primary City ID
20
(??)_
Primary CS ID
21
(??)
Primary Sub ID
22
(????)
Device Address
23
(12)_
NOTE: The Remote Access option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
Remote Access Y/N
24
(N)_
25
Direct Wire
Y/N
(N)_
4204/
ZONE
ENTRY
2-4204
TRIG.
Important Information Regarding Primary (Questions 20-22)
Section 3: Programming the 7847i/7847i-E
OPTIONS
Re-enter the 10-digit Installation Key to verify key.
[0-9]
If verification fails, "Verify NOT OK" will be
displayed for one second and the display will
return to the entry of the installation key.
[01-99]
Enter the 2-digit primary city ID, 01-99 (decimal).
[01-FE]
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
[0001-9999]
9999 (decimal).
The 7847i/
[01-15]
panel as a 4204 relay module. Enter the
appropriate address. For VISTA-10P, and
FA130CP Series control panels, this must be
address 12. For other controls, see the control
panel's Installation and Setup Guide.
NOTES:
1. The 4204 protocol limits address range to 01-15.
If using 2-4204 mode, the 7847i/7847i-E assigns
the second 4204 to the next higher device
address (e.g., if entering address 12 for the first
4204, then address 13 is automatically assigned
to the second 4204 module). Program the control
panel accordingly.
2. The device address(es) must be unique from the
"Keypad Address" entered in Prompt 26 and any
other address used on the control panel.
Press [Y] to allow the end user to access their
[Y], [N]
system via a website. Availability of this service is
controlled by the dealer via the web-based
programming tool on the AlarmNet Direct website.
Applies only to VISTA-128BP/250BP and FBP
[Y], [N]
Series controls, and FA1600C and FA1700C
series controls.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 24: Remote Access is
disabled, skip to Prompt 27: "Supervision."
DESCRIPTION
7847i-
E communicates with the control
3-13