System Status Displays - Honeywell AlarmNet 7847i-E Installation And Setup Manual

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents

Advertisement

7847i/7847i-E Installation and Setup Guide
[F]

System Status Displays

[S]
[T]
5-2
DHCP
OK/BAD
Testing Gateway
ECP 67 Tm
Flt
xx 5
OK
1234 67 Tm
Flt
5555 xx 5
OK
12345678 Tm
Flt
5555555x 5
OK
1234567 Tm
Flt
5555555 5
OK
Test Msg Sent
DHCP (Dynamic Host Configuration Protocol) indicates
server is performing satisfactorily.
Press the [space] key to go to the Physical Link display.
Run Network Diagnostic Test
Performs a set of network diagnostics that tests the
integrity of the links between the unit and the various
connection points (Redirs) to AlarmNet. Refer to
Section 6: Network Diagnostics.
ECP Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
4204 Emulation Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Two-4204 Emulation Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Zone Trigger Mode
The status of the unit can be viewed on the 7720P. The
status display includes:
Zone input status (1234567) - the
numbers 1-7 represent the 7 mappings of
the zone input, and follow Honeywell's
ADEMCO high-speed format codes:
1 = New Event
5 = Normal
X = Not Enabled
• Tm – Tamper status follows high-speed format
codes above.
• Flt – Represents radio faults:
OK = Normal ; No fault
I – No network connectivity over IP and
fault time has expired
i – No network connectivity over IP and
fault time has NOT yet expired.
NOTE: The 7720P will not operate if the power line
voltage is removed.
Test Alarm
Sends a test alarm to AlarmNet only if Private LAN is
not enabled; otherwise, it is sent the Primary CS IP and
the Secondary if it is enabled.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alarmnet 7847i

Table of Contents