Honeywell AlarmNet 7847i-E Installation And Setup Manual page 37

Internet/intranet communication modules with remote services
Hide thumbs Also See for AlarmNet 7847i-E:
Table of Contents

Advertisement

Possible Errors When Configured for AlarmNet-i
Displayed if no response to the registration request is
Registration BAD
received.
Timed Out
Indicates the city, central station, or customer number
Registration BAD
for the Primary account(s) is not accepted. The ID
Pri Sub ID BAD
information was either entered in error, or the central
station failed to pre-authorize programmed ID numbers
with AlarmNet customer service.
Indicates the city, central station, or customer number
Registration BAD
for the Secondary account is not accepted. The ID
2nd Sub ID BAD
information was either entered in error, or the central
station failed to pre-authorize programmed ID numbers
with AlarmNet customer service.
Displayed when both Primary and Secondary subscriber
Registration BAD
IDs are invalid.
Pri&Sec  IDs BAD
Displayed if this is a repair/replacement, or an error was
Registration BAD
made in programming the Primary account information
Pri ID – Need PIN
of 7847i/7847i-E for an existing account. This prompt
appears for 2 seconds. See the Replacing an existing
module section below for further displays.
Displayed if this is a repair/replacement, or an error was
Registration BAD
made in programming the Secondary account
2nd ID – Need PIN
information of 7847i/7847i-E for an existing account.
This prompt appears for 2 seconds. See the Replacing
an existing module section below for further displays.
Displayed if this is a repair/replacement, or an error was
Registration BAD
made in programming BOTH the Primary and
Pri&2nd – Need PIN
Secondary account information of 7847i/7847i-E for an
existing account. This prompt appears for 2 seconds.
See the Replacing an existing module section below for
further displays.
Replacing an existing module using the programming tool
This prompt appears after pressing the down arrow [↓ ↓ ↓ ↓ ]
Enter PIN#
on the 7720P.
NOTE: If it is necessary to exit registration mode, press
ESC from the 7720P programming tool.
Enter a 4-digit alphanumeric PIN number provided by
an authorized AlarmNet representative.
Press the [ENTER] key.
The registration message is sent and the unit waits for
Registering ...
acknowledgement.
If the PIN is valid, the new 7847i/7847i-E is registered
Registration
and the old unit unregistered. Additionally, AlarmNet
SUCCESS
sends a substitution alarm to the central station.
Section 4: Registration
4-3