7847i/7847i-E Installation and Setup Guide
PROMPTS
Enable Zn7 Y/N
42
(N)_
Zn7 Trigger Type
43
(V)_
Invert Zn7 Y/N
44
(N)_
Restore Zn7 Y/N
45
(Y)_
Delay Zn7 (secs)
46
(00)_
Use DHCP Y/N
47
(Y)_
NIC IP Address:
48
255.255.255.255_
Subnet Mask:
49
255.255.255.255_
Gateway IP Addr:
50
255.255.255.255_
DNS Serv IP Addr:
51
255.255.255.255_
NOTE: The "Enable Pwr Save" option is not available, and is not displayed, if Private LAN is enabled on the 7847i-E.
Enable Pwr Save
52
(Y)_
Review? Y/N
53
3-8
ENTRY
OPTIONS
[Y], [N]
• (V+)
• (V–)
• (EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
12 digit:
xxx.xxx.xxx.xxx
12 digit:
xxx.xxx.xxx.xxx
12 digit:
xxx.xxx.xxx.xxx
[0.0.0.0.] = not
used
12 digit:
xxx.xxx.xxx.xxx
[0.0.0.0.] = not
used
[Y], [N]
[Y] = review
[N] = exit
DESCRIPTION
Enables alarm reporting for zone 7.
If [N], skip to Prompt 47: "Use DHCP."
Selects the triggering method for this zone input.
Press the [space] key to scroll choices.
Inverts the alarm and normal states of the zone 7
trigger; otherwise, uses normal input signal.
Enables restore reporting for zone 7.
Defines the reporting delay in seconds for zone 7.
Dynamically allocates the IP addresses (recommended);
then skip to Prompt 53: "Review?"
If [N], uses fixed IP addresses.
Enter the 4-part address for this device. The four parts
of the address must be separated by spaces (displayed
as periods in Review mode).
Enter the 32-bit address mask used to indicate the
portion (bits) of the IP address that is being used for
the subnet address. The four parts of the address must
be separated by spaces (displayed as periods in Review
mode).
Enter the 4-part address assigned to the Gateway. The
four parts of the address must be separated by spaces
(displayed as periods in Review mode).
Enter the 4-part IP address assigned to the DNS
(Domain Name System) server. The four parts of the
address must be separated by spaces (displayed as
periods in Review mode).
For 24 hour UL Battery Backup requirement, this
feature must be enabled, or the unit must be powered
by an appropriate UL listed UPS. If connectivity
problems occur with certain routers or switches disable
this option.
This option is forced to [N] when Private LAN is
enabled.
Reviewing Programming Mode Entries
To review the programming options (to ensure that the
correct entries have been made), press [Y]. The
programming prompts are displayed again. Use the
up/down arrow keys to scroll through the program
fields without changing any of the values. If a value
requires change, simply type in the correct value. When
the last field is displayed, the "REVIEW?" prompt
again appears.
To exit the programming mode, press [N] in
response to the "REVIEW?" prompt, and refer to
Exiting Programming Mode at the end of this section.