PROMPTS
Open/Close Zone
35
(0)_
Zn1 Trigger Type
36
(V+)_
Invert Zn1 Y/N
37
(N)_
Restore Zn1 Y/N
38
(Y)_
Delay Zn1 (secs)
39
(00)_
Rpt Zn1 ONLY if
40
Armed (N)_
Invert Zn2 Y/N
41
(N)_
Restore Zn2 Y/N
42
(Y)_
Delay Zn2 (secs)
43
(00)_
Rpt Zn2 ONLY if
44
Armed (N)_
If Lynx Panic is enabled, then skip to Prompt 49: "Rpt Zn3 ONLY if Armed."
Zn3 Trigger Type
45
(V+)_
Invert Zn3 Y/N
46
(N)_
4204/
ZONE
ENTRY
2-4204
TRIG.
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
• (EOLR)
• (V+)
• (V–)
[Y], [N]
[Y], [N]
[01-15]
[00]=no delay
[Y], [N]
Section 3: Programming the 7847i/7847i-E
OPTIONS
Enter the zone number to be used for open/close
(arm/disarm) reports.
This zone assignment must be unique from the
Telco Zone selected in Prompt 34.
Zone Trigger Mode: If any zone is programmed
for "report only if armed," zone 7 cannot be used
as an open/close zone. If Lynx Panic is enabled,
zone 3 cannot be used.
4204 Mode: If any zone is programmed for "report
only if armed," zone 4 cannot be used as an
open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled,
zone 8 cannot be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm)
trigger (or relay output) from the control panel to
the open/close zone.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 1
trigger; otherwise uses normal input signal.
Enables restore reporting for zone 1.
Defines the reporting delay in seconds for zone 1.
[Y], [N]
Report alarms on zone 1 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
Inverts the alarm and normal states of the zone 2
trigger; otherwise uses normal input signal.
[Y], [N]
Enables restore reporting for zone 2.
[01-15]
Defines the reporting delay in seconds for zone 2.
[00]=no delay
[Y], [N]
Reports alarms on zone 2 ONLY if the conditional
zone (zone 7 in zone trigger mode; zone 4 in 4204
mode; zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 2.
• (EOLR)
Selects the triggering method for this zone input.
• (V+)
Press the [space] key to scroll through choices.
• (V–)
[Y], [N]
Inverts the alarm and normal states of the zone 3
trigger; otherwise uses normal input signal.