7847i/7847i-E Installation and Setup Guide
transmission of messages, and can be programmed to send reports only when a conditional
zone is triggered (armed), (see Zone Input Options later in this section).
In single 4204 mode, the unit supports up to four relay-zones. In two-4204 mode, the unit
functions as two 4204 modules, supporting up to eight relay-zones.
4204 Relay Outputs map
First 4204 Zones
(device address entered in Prompt 23):
Relay 1 = Zone 1
Relay 2 = Zone 2
Relay 3 = Zone 3
Relay 4 = Zone 4 or conditional zone trigger if
NOTE: Zone 4 status is not reported when
being used as the conditional (armed) trigger
zone.
When using the 7847i/7847i-E in 4204 Emulation Mode, DO NOT enable the Long-Range
Radio module in control panel programming. Instead, enable 4204 relay module address(es)
and program the appropriate relay activation functions for the relay-zones being used. In
some control panels, it is called "relay programming" and in others it is called "output device
programming." It is recommended that the "close and stay closed" (usually choice 2) action is
selected. Selection of momentary activation will cause the unit to generate an alarm and NOT
a restore, even if the unit is programmed to send a restore for the given zone.
In 4204 mode, messages are reported in ADEMCO High-Speed format. Zone alarms (status
7) are reported with "1" (alarm) or "3" (restore) displayed in the zone position for the
respective zone (e.g. alarm on zone 2: 5155 5555 7; restore 5355 5555 7). A supervision fault
trouble message is automatically sent if the module detects no activity on its connection to
the control. The message is: 5555 5515 5; restore message is: 5555 5535 5.
Refer to Table 5 for 4204 Emulation Mode programming and follow the prompts that pertain
to 4204 or Two-4204 mode. A check mark (
mode.

Alternative Mode Programming

Press the [ENTER] key to begin programming
operation being programmed.
NOTE: The central station can remotely block access to
Table 5: Programming a 7847i/7847i-E for Zone Trigger, 4204 Emulation, or Two-4204 Emulation modes.
PROMPTS
Strt Prog Mode?
1
Y/N_
Enter Password
2
Program Device?
3
Y/N_
3-10
to 7847i/7847i-E
"report only if armed" is selected in
any zone 1-3 when using single 4204
mode.
local device programming. If this has been done,
the following prompt appears:
4204/
ZONE
ENTRY
2-4204
TRIG.
zones as follows:
Second 4204 Zones
(device address entered in Prompt 23, plus 1):
Relay 1 = Zone 5
Relay 2 = Zone 6
Relay 3 = Zone 7
Relay 4 = Zone 8 or conditional zone trigger if
"report only if armed" is selected in
any zone 1-7 when using two-4204
mode.
NOTE: Zone 8 status is not reported when
being used as the conditional (armed) trigger
zone or if tamper reporting is enabled.
) indicates whether the prompt applies to that
ollow the prompts for the mode of
and f
Access to Prog
Mode Denied
OPTIONS
Enters programming mode.
[Y], [N]
[0-9, A-F, N,
If a password has been previously assigned, this
S, T, X, Y]
prompt appears.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
The next prompt appears.
[Y], [N]
To begin programming the module, press [Y] and
go to Prompt 9: "Device Mode."
To create a password if none has been assigned,
press [N] and go to Prompt 4: Create Password.
To change an existing password, press [N] and go
to Prompt 5: "Change Password."