1.
Specifications
1.1

Outdoor Units

Model Name
#
1 Cooling Capacity (19.5°CWB)
#
2 Cooling Capacity (19.0°CWB)
#
3 Heating Capacity
Casing Color
Dimensions: (H×W×D)
Heat Exchanger
Type
Displacement
Number of Revolutions
Comp.
Motor Output×Number
of Units
Starting Method
Type
Motor Output
Fan
Air Flow Rate
Drive
Liquid Pipe
Connecting
Gas Pipe
Pipes
Oil Equalizing Pipe
Machine Weight
Safety Devices
Defrost Method
Capacity Control
Refrigerant Name
Refrigerant
Charge
Control
Refrigerator
Oil
Charge Volume
Standard Accessories
Drawing No.
Notes:
#
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m,
#
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m,
#
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m,
10
RXYQ5MY1B
kcal / h
Btu / h
kW
kW
kcal / h
Btu / h
kW
Ivory White (5Y7.5/1)
mm
1600×635×765
Cross Fin Coil
Hermetically Sealed Scroll Type
m³/h
r.p.m
kW
Propeller Fan
kW
m³/min
Direct Drive
φ
mm
9.5 (Flare Connection)
φ
mm
15.9 (Flare Connection)
mm
kg
High Pressure Switch, Fan Driver Overload Protector,
Inverter Overload Protector, Fusible Plugs
%
kg
Electronic Expansion Valve
Synthetic (ether) oil
L
Installation Manual, Operation Manual, Connection Pipes,
Clamps
4D038964A
level difference : 0m.
level difference : 0m.
level difference : 0m.
12,500
49,500
14.5
14.0
13,800
54,600
16.0
13.72
6480
3.2×1
Soft start
0.35×1
75
160
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
Deicer
24~100
R410A
5.6
1.2
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Si39-302
RXYQ8MY1B
20,000
78,900
23.1
22.4
21,500
85,400
25.0
Ivory White (5Y7.5/1)
1600×930×765
Cross Fin Coil
Hermetically Sealed Scroll Type
13.72+10.47
6480, 2900
(1.2+4.5)×1
Soft start
Propeller Fan
0.75×1
175
Direct Drive
φ
9.5 (Flare Connection)
φ
19.1 (Brazing Connection)
230
Deicer
14~100
R410A
8.6
Electronic Expansion Valve
Synthetic (ether) oil
1.9+1.6
4D038965A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Specifications