Kohler Comand Pro CH1000 Service Manual page 95

Table of Contents

Advertisement

Remove Governor Yoke, Cross Shaft, and
Seal
1. Remove the two mounting screws securing the
yoke to the governor cross shaft . See Figure 8-61.
Figure 8-61. Removing Cross Shaft/Yoke Screws.
2. Pull the governor cross shaft out of the crankcase
and remove the seal.
Remove Lifter Feed Chamber Cover and
Gaskets
1. Remove the three screws securing the lift er feed
chamber baffl e (some models only), cover, and
gaskets. Carefully separate the parts from the
crankcase. See Figure 8-62.
Screws
Screws
Figure 8-62. Removing Lifter Feed Chamber Cover
Components.
Remove Flywheel and PTO End Oil Seals
1. Remove the oil seals from the crankcase and
closure plate using a seal puller. See Figure 8-63.
Figure 8-63. Removing Oil Seals.
Removal of Main Bearings
NOTE: Flywheel and PTO side main bearings
Baffl e (Some
Baffl e (Some
Models Only)
Models Only)
Figure 8-64. Support Surface Details.
Cover
Cover
Gasket
Gasket
should only be removed if replacement
is required due to wear. If removal is
performed, use a press and support the
casting surface around the bearing fl ange. Do
not press against or support by the gasket/
outer perimeter surface. See Figure 8-64.
Support
This Surface
Section 8
Disassembly
8
8.15

Advertisement

Table of Contents
loading

This manual is also suitable for:

Comand pro ch940

Table of Contents