Kohler Comand Pro CH1000 Service Manual page 50

Table of Contents

Advertisement

Section 6
Lubrication System
7. Fill the crankcase with new oil of the proper type
to the F mark on the dipstick.
8. Start the engine and check for oil leaks. Correct
any leaks before placing the engine into service.
Check oil level to be sure it is up to but not over
the F mark.
Service Oil Cooler
These engines are equipped with an oil cooler
mounted under the No. 2 side cylinder shroud,
separate from the oil fi lter. See Figure 6-9.
Oil
Cooler
Cylinder
Shroud
Figure 6-9. Oil Cooler.
Inspect and clean the oil cooler every 150 hours of
operation (more frequently under severe conditions).
In order to be eff ective, the oil cooler must be kept free
of debris.
To service the oil cooler, clean the outside of fi ns
with a brush, vacuum, or compressed air. If required,
remove the two screws holding the cooler unit to the
backing shroud assembly. Carefully pull the cooler
outward and clean the underside. Aft er cleaning,
reinstall the oil cooler to the backing shroud with the
two mounting screws.
Figure 6-10. Cleaning Top of Oil Cooler.
6.4
Oil
Cooler
Figure 6-11. Cleaning Underside of Oil Cooler.
Oil Sentry™
General
Some engines are equipped with an optional Oil
Sentry™ switch. This switch is designed to prevent
the engine from starting in a low oil or no oil
condition. The Oil Sentry™ may not shut down
a running engine before damage occurs. In some
applications this switch may activate a warning signal.
Read your equipment manuals for more information.
Figure 6-12. Oil Sentry™ Pressure Switch.
Installation
The Oil Sentry™ pressure switch is installed in
the closure plate pressure port. See Figure 6-12.
On engines not equipped with Oil Sentry™ the
installation hole is sealed with a 1/8-27 N.P.T.F. pipe
plug.
To install the switch, follow these steps:
1. Apply pipe sealant with Tefl on
®
PST
Thread Sealant or equivalent) to the threads
of the switch.
2. Install the switch into the tapped hole in the
closure plate. See Figure 6-12.
Pressure Switch
Pressure Switch
®
(Loctite
®
592™