Kohler Comand Pro CH1000 Service Manual page 83

Table of Contents

Advertisement

Mounting
Screws
Figure 8-7. Removing Electric Starter.
Remove Air Cleaner Assembly
1. Disconnect the breather hose from the air cleaner,
and the formed vent hose from the vent port on
the carburetor.
2. Remove the four hex fl ange nuts, ground lead,
and choke return spring bracket from the
mounting studs. See Figure 8-8.
Mounting
Breather
Breather
Hose
Bracket
Figure 8-8. Air Cleaner Mounting Details.
3. Remove the two screws securing the air cleaner
and main control bracket to the intake manifold
bosses. See Figure 8-9.
NOTE: The low-profi le air cleaner is removed the
same way as the heavy-duty air cleaner.
Vent Hose
Nuts
Mounting
Screws
Figure 8-9. Mounting Screws.
4. Remove the air cleaner as an assembly from the
engine. See Figure 8-10.
Figure 8-10. Removing Air Cleaner Assembly.
Removing Control Bracket, Governor
Springs, and Lever
1. Unhook the governed idle and governor springs
from the controls on the main bracket and
governor lever. Note the color, location and
position of each. See Figure 8-11.
2. Disconnect the thrott le linkage and dampening
spring from the governor lever at the small
bushing. See Figure 8-11.
Section 8
Disassembly