8. Take out the drive lever and pull the armature
out of the drive end cap. See Figure 7-31.
9. Remove the thrust washer from the armature
shaft . See Figure 7-31.
Figure 7-31. Armature and Lever Removed.
10. Push the stop collar down to expose the retaining
ring. See Figure 7-32.
Figure 7-32. Retaining Ring Detail.
11. Remove the retainer from the armature shaft .
Save the stop collar.
NOTE:
Do not reuse the old retainer.
Electrical System and Components
Figure 7-33. Removing Retaining Ring.
12. Remove the drive pinion assembly from the
armature.
13. Clean the parts as required.
NOTE: Do not soak the armature or use solvent
when cleaning. Wipe clean using a soft cloth,
or use compressed air.
Drive
End Cap
Collar
Retaining Ring
Stop
Drive
Armature
Washer
Tube
Figure 7-34. Delco-Remy Starter.
Section 7
Screw
7
Plunger
Spring
Lever
Plate
Plug
Solenoid
Frame & Field
Brush Holder
Nut
Commutator
End Plate
Screw
Bolt
7.21