MAINTENANCE.
Antifreeze is flammable, so keep it away from any flame.
Use city water for the cooling water.
G
If river water, well water or other such water supply must be
used, contact your Komatsu distributor.
We recommend use of an antifreeze density gauge to control
G
the mixing proportions.
When removing drain plug, avoid pouring coolant on your-
self.
REMOVAL
Hot, scalding coolant can spray out if the radiator cap is
G
removed suddenly. Relieve system pressure by slowly
turning the cap to the first notch or lifting the safety lever
(if equipped). Remove the cap only after the pressure is
relirved.
Use extreme caution when adding coolant to the radiator
G
to avoid being burned. Wear gloves and goggles and
keep face away from the filler neck.
To remove the cap, turn the cap to the left, or counterclockwise up
to the safety stop until the cap is free to be removed.
INSTALLATION
When installing the cap, the gasket and contacting surfaces must
be clean. Turn the cap to the right, or clockwise until snug.
WARNING
WARNING
WARNING
SERVICE PROCEDURE