20. Maintenance
WARNING!: Failure to maintain your door may
void the warranty on your door opener.
CAUTION: Door adjustments should only be
carried out by experienced persons, as this
function can be dangerous if not performed
under strict safety procedures
20.1 Door Maintenance
The door should be tested manually regularly to ensure it
is in good condition. A poorly maintained door could cause
fatal or serious injuries or serious damage to property.
Therefore it is recommended:
• Frequently examine the door, particularly the cables,
springs and mountings for signs of wear, damage or
imbalance. DO NOT USE if repair or adjustment is
needed since a fault in the installation or an incorrectly
balanced door may cause injury.
20.2 Lubrication (every 3 - 6 months)
To ensure a long and trouble free life for your door the
following is recommended:
• Lubricate the drive chain.
• Guide Tracks: Clean the internal sections of the guide
tracks with a cloth dampened with mineral turps or
methylated spirits.
•
20.3 Door Service and Repair
If correct maintenance and servicing are not carried out,
warranty may be void. To keep your door running well, it is
recommended that your door be serviced by an experienced
technician, every
12 months
• Check the manual operation of the door by using the
hand chain.
• Fasterners: Check all screws, nuts and bolts to ensure
they are secure.
Service Record
Record any maintenance in the following table to assist in any warranty service.
Date
Service by Company Name Print Name
20
Axess
Pro 1505
®
or earlier if required:
Installation Instructions
ELECTROCUTION!
power cord from the mains power before
making any door repairs / maintenance or
removing the opener button cover.
20.4 Opener Maintenance
To ensure a long and trouble free life for your opener the
following is recommended:
• Monthy:
i. Check the tension, condition and alignment of the
drive chain. Adjust / replace if required.
ii. Check the operation of the Safety Beams.
• Quarterly:
i. Check tightness of the fixing bolts and grub screw of
the sprocket.
NOTE: If the door does not operate smoothly, call your
industrial door professional.
20.5 Service Indicator
As a reminder the Axess Pro 1505 has a built in maintenance
counter. This counter has a factory default of 60,000 cycles,
and it is adjustable from 0 to 60,000 cycles. When this counter
expires, at the start of each door movement the beeper will
sound three times and "SERVICE DUE" message displays on
the console.
At this time Automatic Technology recommends you contact
your industrial door professional to perform an annual door
service.