7 — DIAGNOSTICS & TROUBLESHOOTING
36
Type 2 Fault Codes
When Fault Code Type parameter is set to 1, the status LED uses the fault
codes listed in Table 2-2. Six single-digit codes are used: 2, 3, 5, 6, 7, and 9.
Table 2-2 STATUS LED FAULT CODES, TYPE 2
TYPE 2 LED CODES
LED off
solid on
2
¤¤
3
¤¤¤
5
¤¤¤¤¤
6
¤¤¤¤¤¤
7
¤¤¤¤¤¤¤
9
¤¤¤¤¤¤¤¤¤
=
Must cycle keyswitch to clear.
=
Must use programmer to clear, as follows: select Program menu,
alter data value of any parameter, cycle keyswitch.
FAULT
no power or defective controller
controller powered up; no faults
UNDERVOLTAGE FAULT
OVERVOLTAGE FAULT
BRAKE ON FAULT
HPD FAULT
WIRING FAULT ❊
SPEED POT FAULT
THROTTLE FAULT
BATTERY DISCONNECT FAULT ❊
BRAKE OFF FAULT
CURRENT SENSE FAULT ❊
EE CHECKSUM FAULT †
HARDWARE FAILSAFE ❊
MAIN FAULT ❊
MAIN OFF FAULT
MAIN ON FAULT
PRECHARGE FAULT ❊