3 — PROGRAMMABLE PARAMETERS: Compensation and Miscellaneous Parameters;
PARAMETER
IR Comp
Anti-Rollback Comp
PARAMETER
Sleep
Fault Code Type
Reset Drive Time
22
COMPENSATION MENU
ALLOWABLE
RANGE
0–100 %
Sets the motor load compensation. Higher values provide stronger
disturbance rejection, while lower values provide smoother operation.
Note: Allowable range is restricted by the Anti-Rollback Comp setting.
0–125 %
Sets the motor load compensation after the throttle is released to neutral
and the speed is estimated to be near zero. Higher values provide more
hill-holding force.
Note: Allowable range is restricted by the IR Comp setting.
MISCELLANEOUS MENU
ALLOWABLE
RANGE
0–60 min
Sets the delay time between the last throttle request or serial
communication and when the controller goes into sleep mode.
Setting the delay to zero disables the sleep function.
0–2
This parameter selects which set of fault identification codes
(Type 0,1, or 2) will be flashed by the status LED; see Section 7.
On/Off
The controller's hourmeter logs the total drive time since the last reset;
this record is accessible through the Monitor menu. Setting this parameter
On zeroes the hourmeter and starts a new log; this is typically done when
the vehicle is serviced. Reset Drive Time is automatically set to Off after
the hourmeter is reset.
CLONING
(for copying parameter settings to multiple controllers)
Once a controller has been programmed to the desired settings, these settings
can be transferred as a group to other controllers, thus creating a family of
"clone" controllers with identical settings. Note: Cloning only works between
controllers with the same model number and software version. For example,
the programmer can read all the information from a 1212-2201 controller and
write it to other 1212-2201 controllers; however, it cannot write that same
information to 1212-2202 controllers.
To perform cloning, plug the 1311 programmer into the controller that
has the desired settings. Scroll down to the Functions menu, and select "Get
Settings From Controller" to copy the settings into the programmer.
Then plug the programmer into the controller that you want to have
these same settings, and select "Write Settings To Controller."

Controller Cloning