PARAMETER
Type
PotHigh
PotLow
Neutral Deadband
Throttle Max
HPD
Speed Limit Pot
Curtis 1212 Manual
THROTTLE MENU
ALLOWABLE
RANGE
0–9
The 1212 controller can accept inputs from both 5kΩ, 3-wire pot throttles
and voltage throttles. Set the throttle type parameter to match the throttle
used in your application.
5k Ω , 3-wire pot throttles
0 = wigwag
1 = inverted wigwag
2 = single-ended; neutral when wiper at PotLow
3 = inverted single-ended; neutral when wiper at PotHigh
4 = unipolar.
Voltage throttles
5 = wigwag
6 = inverted wigwag
7 = single-ended; neutral when wiper ≤ PotLow
8 = inverted single-ended voltage; neutral when wiper ≥ PotHigh
9 = unipolar
Note: If Throttle Type 5–9 is used, see note on page 8.
3–5 V
Sets the maximum voltage for voltage throttles (Types 5–9).
(For 5kΩ, 3-wire pot throttles, PotHigh is determined by the throttle itself.)
0–2 V
Sets the minimum voltage for voltage throttles (Types 5–9).
(For 5kΩ, 3-wire pot throttles, PotLow is determined by the throttle itself.)
5–30 %
Sets the throttle range the controller interprets as neutral. Increasing the
parameter setting increases the neutral range. This parameter allows the
neutral deadband to be defined wide enough to ensure the controller goes
into neutral when the throttle is released.
Guidelines for adjusting this parameter are provided in Section 5.
40–100 %
Sets the pot wiper voltage required to produce 100% controller output.
Increasing the Throttle Max setting reduces the wiper voltage required,
and therefore reduces the stroke necessary to produce full output. This
feature allows reduced-range throttle assemblies to be used.
Guidelines for setting Throttle Max are provided in Section 5.
On/Off
When programmed On, vehicle drive is inhibited if a throttle command
outside the neutral deadband is issued before the controller is powered up.
Drive will continue to be inhibited until the throttle is returned to within the
neutral deadband. If the HPD fault is not cleared within 10 seconds,
a wiring fault is declared and a power cycle is required.
On/Off
This parameter is used to enable/disable the speed limit pot. If no speed
limit pot is used, set Speed Limit Pot to Off.
3 — PROGRAMMABLE PARAMETERS:
DESCRIPTION

Throttle Parameters

15