Parameter
Function
Period
The motion detection function becomes activated in the specified
periods. See Figure 5-45.
There are six periods in one day. Please check the box to enable
the corresponding period.
Click the save button and the system goes back to the motion
detection interface. Please click the save button to exit.
The system only records one event during the anti-dither period.
Anti-dither
The value ranges from 5s to 600s.
The sensitivity uses percentages. 100% is the highest sensitivity.
Sensitivity
Region
If you select the motion detection type, you can click this button to
set the motion detection zone. The interface is shown as in Figure
5-46. Here you can set the motion detection zone. There are four
zones for you to set. Please select a zone first and then left click
and drag the mouse to select a zone. The corresponding color
zone displays different detection zones. You can click the Fn
button to switch between the arm mode and disarm mode. In the
arm mode, you can click the direction buttons to move the green
rectangle to set the motion detection zone. After you have
completed the setup, please click the ENTER button to exit
current setup. Do remember to click the save button to save the
current setup. If you click the ESC button to exit the region setup
interface, the system will not save your zone setup.
Record
The system auto activates motion detection channel(s) to record
channel
once an alarm occurs. Please note you need to set a motion
detect recording period and go to Storage-> Schedule to set the
current channel as schedule record.
The system can delay the recording for a specified time after the
Record Delay
alarm ends. The value ranges from 10s to 300s.
Enable the alarm activation function. You need to select an alarm
Alarm out
output port so that system can activate the corresponding alarm
device when an alarm occurs.
The system can delay the alarm output for a specified time after
Latch
an alarm ended. The value ranges from 1s to 300s.
Show
The system can pop up a message to notify you on the local host
message
screen if you enabled this function.
Buzzer
Check the box here to enable this function. The buzzer beeps
when an alarm occurs.
Alarm upload
The system can upload the alarm signal to the alarm center.
Message
When a 3G network connection is correct, the system can send
out a message when motion detect occurs.
Send Email
If you enabled this function, the system can send out an email to
alert you when an alarm occurs.
You need to check the box here to enable this function. The
Tour
system begins a 1-window or multiple-window tour display among
the channel(s) you set to record when an alarm occurs.
PTZ
Here you can set the PTZ movement when alarm occurs. Such as
Activation
go to preset X. See Figure 5-47.