Diagnostics
The Fault Tolerant Server series provides the self-check diagnosis function for some components. If a fault occurs in a
component, the Fault Tolerant Server series can diagnose the component to detect the fault.
To diagnose a component with the NEC ESMPRO Manager, use the [Maintenance] tree of the component in the data
viewer. Open the tree of the component to be diagnosed and select the [Maintenance] tree.
To diagnose of a component with the ft server utility, use the utility screen of the component.
The table below shows the potential cases in which a component is to be diagnosed.
Component
CPU Module
When a phenomenon causing the
module to be down occurs or a
phenomenon supposed to be a
malfunction occurs.
Executable in any of the following
module states (this can be viewed on
manager screen):
Removed
Broken
Shot
Firmware Update Complete
To diagnose the module under
operation, bring down the module
before the diagnosis.
PCI Module
Same as above
Remote: Executable from remote management PC by using NEC ESMPRO Manager
Local:
Executable on local server by using ft server utility
–: Not support
Diagnosis
Remote
When a phenomenon causing the
module to be down occurs or a
phenomenon supposed to be a
malfunction occurs.
Executable in any of the following
module states:
Only the status LED 1 illuminates
amber when the module is in one the
following states:
To diagnose the module under
operation, bring down the module
before the diagnosis.
Same as above
5-46
Local
When the status LED 1 is red and
the status LED 2 is off
Removed
Broken
Shot
Firmware Update Complete
(no fault found by diagnosis)