Vehicle 10-60VDC Direct Power Connection
1. The Thor VM2 must not be mounted in the dock. The power switch on the dock must be turned Off. The power
cable must be UNPLUGGED from the dock.
2. While observing the
actual battery terminals of the vehicle (if using unswitched power).
3. Use proper electrical and mechanical fastening means for terminating the cable. Properly sized "crimp" type
electrical terminals are an accepted method of termination. Please select electrical connectors sized for use
with 20AWG (0.81mm2) conductors.
4. Refer to the wiring diagrams following this section for wire colors and connections:
Ignition Control Wiring Diagram
Auto-On Control Wiring Diagram
Manual Control Wiring Diagram
5. Route the power cable the shortest way possible removing any left-over cable. The cable is rated for a maxi-
mum temperature of 105°C (221°F). Therefore, when routing this cable it should be protected from physical
damage and from surfaces that might exceed this temperature. Cable should be protected from physical dam-
age from moving parts. Do not expose the cable to chemicals or oil that may cause the wiring insulation to
deteriorate. Always route the cable so that it does not interfere with safe operation and maintenance of the
vehicle.
6. Provide mechanical support for the cable by securing it to the vehicle structure at approximately one foot inter-
vals, taking care not to over tighten and pinch conductors or penetrate outer cable jacket.
7. Connect the watertight connector end of the power cable to the Thor VM2 dock power connector by aligning
the connector pins to the power connector; push down on the watertight connector and twist it to fasten
securely.
8. Secure the power cable to the Thor VM2 using the
9.
Place Thor VM2 in the Dock
10. If using the
11. Press the
12. Press the
Once installation is complete, remember to start the Thor VM2 and select the desired Power Configuration Mode
to enable Auto-On, Ignition Control or Manual Control of the Thor VM2 boot up process.
See the
Power Configuration Mode
4 - 20
Fuse Requirements
(page 4-21)
(page 4-23)
(page 4-2)
Screen Blanking
(page 4-35) feature, install the screen blanking box or switch.
Power Switch
(page 3-6) on the back of the Thor VM2 dock.
Power Button
(page 3-6) on the front of the Thor VM2 to turn on the Thor VM2.
(page 5-83) control panel.
(page 4-19), connect the power cable as close as possible to the
(page 4-22)
Strain Relief Cable Clamps
(page 4-16).